• Designation SMX 5X
    Maximum no of extension componentries -
    Safe Digital I -
    Safe Digital I/O -
    Safe Digital Out -
    Safe Analogue-In -
    Safe Relay Outputs -
    Standard Outputs -
    Signature Pulse Outputs -
    Integrated Communication interface (For one interface only) Profisafe, Devicenet, CAN 2.0, CAN open, Profinet, Ether CAT.
    No. of monitored axis -
    Encoder interface -
    Supply Voltage Supply by basic componentry
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay -
    Size (HxTxB[mm]) 100x115x22.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 4X
    Maximum no of extension componentries -
    Safe Digital I -
    Safe Digital I/O -
    Safe Digital Out -
    Safe Analogue-In -
    Safe Relay Outputs -
    Standard Outputs -
    Signature Pulse Outputs -
    Integrated Communication interface (For one interface only) Profisafe via, profibus, Profinet
    No. of monitored axis -
    Encoder interface -
    Supply Voltage Supply by basic componentry
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay -
    Size (HxTxB[mm]) 100x115x22.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 33
    Maximum no of extension componentries -
    Safe Digital I -
    Safe Digital I/O -
    Safe Digital Out -
    Safe Analogue-In 4
    Safe Relay Outputs -
    Standard Outputs -
    Signature Pulse Outputs -
    Integrated Communication interface (For one interface only) -
    No. of monitored axis -
    Encoder interface -
    Supply Voltage Supply by basic componentry
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay -
    Size (HxTxB[mm]) 100x115x45
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 31
    Maximum no of extension componentries -
    Safe Digital I 12
    Safe Digital I/O 10
    Safe Digital Out -
    Safe Analogue-In -
    Safe Relay Outputs -
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis -
    Encoder interface -
    Supply Voltage Supply by basic componentry
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay -
    Size (HxTxB[mm]) 100x115x45
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 12A
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In 2
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis max. 2 (Componentry parameterize able for 1-axis-or-2-axis-mode)
    Encoder interface 1 SSI, SIN/COS, Inkr TTL, Inkr, Proxi-sw
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog +/- 10V
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x67.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 12-2
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis max. 2 (Componentry parameterize able for 1-axis-or-2-axis-mode)
    Encoder interface 2 SSI, SIN/COS, Inkr TTL, Inkr HTL, Resolver, Proxi-sw
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x112.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 12
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis max. 2 (Componentry parameterize able for 1-axis-or-2-axis-mode)
    Encoder interface 1 SSI, SIN/COS, Inkr TTL, Proxi-sw
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x67.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 11-1
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis 1 (1 SSI in combination with other encoder technology)
    Encoder interface 1 SSI, SIN/COS, Inkr TTL, Inkr HTL, Resolver, Proxi-sw
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x67.5
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 11
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis 1 (1 SSI in combination with other encoder technology)
    Encoder interface 1 SSI, SIN/COS, Inkr TTL, Proxi-sw
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x45
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 10
    Maximum no of extension componentries 2
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Integrated Communication interface (For one interface only) -
    No. of monitored axis -
    Encoder interface -
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x45
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • (on the table below swipe left and / or tilt screen horizontally on a mobile device to view table contents)
    Designation SMX 100-4
    Maximum no of extension componentries 6
    Safe Digital I  14
    Safe Digital I/O 40
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 10
    Signature Pulse Outputs 2
    Memory Card Yes
    Integrated Communication Interface (For one interface only) Profibus, Devicent, CAN 2.0, CAN Open, Profinet, Ether CAT.
    No. of monitored axis -
    Encoder Interface -
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x180
       

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 100-2
    Maximum no of extension componentries 6
    Safe Digital I  14
    Safe Digital I/O 20
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 6
    Signature Pulse Outputs 2
    Memory Card Yes
    Integrated Communication interface (For one interface only) Profibus, Devicenet, CAN 2.0, CAN open, Profinet, Ether CAT.
    No. of monitored axis -
    Encoder interface -
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input voltage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x115x135
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>


  • Designation SMX 101
    Maximum no of extension componentries 6
    Safe Digital I  14
    Safe Digital I/O -
    Safe Digital Out 2
    Safe Analogue-In -
    Safe Relay Outputs 1
    Standard Outputs 2
    Signature Pulse Outputs 2
    Memory Card Yes
    Integrated Communication Interface (For one interface only) Profibus, Devicenet, CAN 2.0, CAN open, Profinet, Ether CAT.
    No. of monitored axis -
    Encoder Interface -
    Supply Voltage 24 VDC/2A
    Rated Voltage digital I/O 24VDC
    Max. input volatage analog -
    Max. output current on digital output 0.25A
    Max. current relay 24 VDC/2A, 230 VAC/2A
    Size (HxTxB[mm]) 100x155x90
     

    <<< see below to read more about this product or click here to see more in the SMX 100 range >>>